5-30
GS k m d1...dk NUL Barcode Print
Code
1D
16
+ 6B
16
+ m + d1...dk + NUL
Domain of
function
1 m 7
The values of d1 to dk depend on a type of Barcode.
Function
Selects a type of Barcode and prints the Barcode.
m Type of Barcode
1 UPC-E
2 JAN13
3 JAN8
4 CODE39
5 ITF
6 CODABAR
7 CODE128
Details
This command is finished by a NUL code.
UPCE is the 7-byte Barcode data and internally adds a check digit.
JAN13 is the 12-byte Barcode data and internally adds a check digit.
JAN8 is the 7-byte Barcode data and internally adds a check digit.
CODE39 automatically adds the start and stop modules.
ITF is the even number-byte Barcode data and automatically adds the start and
stop modules.
CODE128 transmits the start module and the Barcode data. And the check digit
and the stop module are automatically added.
If the special characters are included in the data, specify them at 2 bytes as
follows.
SHIFT 7B
16
, 53
16
({S)
CODE A 7B
16
, 41
16
({A)
CODE B 7B
16
, 42
16
({B)
CODE C 7B
16
, 43
16
({C)
FNC 1 7B
16
, 31
16
({1)
FNC 2 7B
16
, 32
16
({2)
FNC 3 7B
16
, 33
16
({3)
FNC 4 7B
16
, 34
16
({4)
{ 7B
16
, 7B
16
({{)
Example) When printing Start Code C, Fnc 1, and 0012, (where n = 7),
send 1D
16
, 6B
16
, 07
16
, 69
16
, 7B
16
, 31
16
, 30
16
, 30
16
, 31
16
, 32
16
, 00
16
in this order.