Seitenansicht 17
3-4
3.3 INSTALLATION
1. How to Install the Fixing Bracket
スペーサーを必要なぶん重ねて使用する。
Figure 3-5 Installing the Fixing Bracket
Use the spacers depending on the fitting panel thickness referring to the next table. If not,
the body may be deformed, and therefore it may be hard to open the paper cover or printing
quality may be deteriorated. (If the fitting panel thickness exceeds 2.2 mm, it may be hard to
tighten the screws.)
Panel thickness
Spacer
thickness
Panel thickness Spacer thickness
1.0 mm None 1.7 to 1.8 mm 0.5 mm and 0.2 mm
1.2 mm 0.2 mm 2.0 mm 1.0 mm
1.5 to 1.6 mm 0.5 mm 2.2 mm 1.0 mm and 0.2 mm
The screw torque is 49 cN m (5 kgf cm).
[Note] Do not touch the end of the DC plug.
2. Setting Paper
(1) Press the paper cover open button, and open the paper cover.
Handle the paper cutter carefully not to cut your hand.
(2) Set a paper roll as shown in the figure.
(3) Close the paper cover by pressing both ends of the cover so the tip end of the paper will
be emerged from the printer.
Use the spacers as much as you need
Seitenansicht 17